5. Connecting the pre-filter to the dryer
1. Connect filter and DRYPOINT AC using proper sealing material and the fittings
supplied.
2. If you are using the integrated
condensate drain: Connect condensate
outlet of filet with the condensate inlet
on the back side of the dryer, using the
tube supplied (4mm) diameter. Apply
another discharge tube from the
condensate outlet on the back side of
the dryer into an oil water separator.
If you are using a BEKOMAT 20FM
condensate drain: Apply a discharge tube
from the condensate drain outlet of the
BEKOMAT 20FM into an oil water
separator.
All tubing should be secured up to the point
of drain to prevent whipping during discharge.
5.1 Recommendation
It is recommended that a bypass line including filter (not supplied) is installed.