Beko CDA 664 F Guida alla Risoluzione dei Problemi Pagina 22

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 21
22 | BEKO TECHNOLOGIES GMBH
8.3 Alarm connection details
To enable the alarm facility it is recommended that a suitable cable is brought into the
controller via the rear panel with a grommet. An external power source is required.:
1. Connect the switching pole of an externally powered alarm device to terminals 1 and
2 of alarm DIN connector.
2. With the power removed from the dryer and the alarm lead wired as described in 1
above, remove the cover from the DIN connection marked ‘Alarm’ and connect the
wired DIN connector ensuring the seal and screw are fitted.
Alarm relay rating 3 Amp Max 28 VDC
Alarm connection type Hirschmann GDS 207
industrial standard DIN
connector or equivalent
Vedere la pagina 21