Operating manual
Maintenance manual
Spare parts
Refrigerating air dryer
DRYPOINT
DRYPOINTDRYPOINT
DRYPOINT
®
®®
®
RA 80
RA 80 RA 80
RA 80-
--
-72
7272
720
00
0
Vedere la pagina 0
1 2 3 4 5 6 ... 71 72

Sommario

Pagina 1 - Refrigerating air dryer

EN Operating manual Maintenance manual Spare parts Refrigerating air dryer DRYPOINTDRYPOINTDRYPOINTDRYPOINT®®®® RA 80 RA 80 RA 80 RA 80----727272720

Pagina 2 - DATA NAMEPLATE

Installation 10 DRYPOINT RA 80 – 720 2.5. Correction factors Correction factor for operating pressure changes: Inlet air pressure barg 4 5 6

Pagina 3 - Index

Installation DRYPOINT RA 80 – 720 11 2.6. Connection to the Compressed Air System DANGER! Compressed air! Operations to be performed by qualifi

Pagina 4 - 4 DRYPOINT RA 80 – 720

Start up 12 DRYPOINT RA 80 – 720 2.8. Electrical connections DANGER! Supply voltage! Qualified personnel should carry out connecting unit to the

Pagina 5 - 1. Safety rules

Start up DRYPOINT RA 80 – 720 13 3.2. First start-up This procedure should be followed on first start-up, after periods of extended s

Pagina 6 - Proper Use of the Dryer

Start up 14 DRYPOINT RA 80 – 720 3.3. Start-up and shut down For short periods of inactivity, (max 2-3 days) we recommend that power is maintaine

Pagina 7 - 2. Installation

Technical Specifications DRYPOINT RA 80 – 720 15 4. Technical Specifications 4.1. Technical Specifications DRYPOINT RA 80-160 /AC 160 16000 960 5

Pagina 8 - 2.3. Installation site

Technical Specifications 16 DRYPOINT RA 80 – 720 4.2. Technical Specifications DRYPOINT RA 180-720 /AC 720 73600 4416 2600 0.26 DN125 PN16 11.00 8

Pagina 9 - 2.4. Installation layout

Technical Specifications DRYPOINT RA 80 – 720 17 4.3. Technical Specifications DRYPOINT RA 80-160 /WC 160 16000 960 565 0.15 1.40 0.37 0.56 1940 3

Pagina 10 - 2.5. Correction factors

Technical Specifications 18 DRYPOINT RA 80 – 720 4.4. Technical Specifications DRYPOINT RA 180-720 /WC 720 73600 4416 2600 0.26 DN125 PN16 8.80 1.

Pagina 11 - DRYPOINT RA 80 – 720 11

Technical description DRYPOINT RA 80 – 720 19 5. Technical description 5.1. Control panel The control panel illustrated below is the only dryer-o

Pagina 12 - 3. Start up

2 DRYPOINT RA 80 – 720 Dear Customer, thank you for choosing our product. In order to get the best performances out of this product, please read thi

Pagina 13 - 3.2. First start-up

Technical description 20 DRYPOINT RA 80 – 720 5.3. Flow Diagram (Air-Cooled) 12.1T6131121cT11b1aPB3 54P111076TS9M8PVAT3T212.112.1T512.1T412.112.1T

Pagina 14 - 3.3. Start-up and shut down

Technical description DRYPOINT RA 80 – 720 21 5.5. Refrigerating compressor The refrigerating compressor is the pump in the system, ga

Pagina 15 - 4. Technical Specifications

Technical description 22 DRYPOINT RA 80 – 720 5.9. Filter Drier Traces of humidity and slag can accumulate inside the refrigerating cir

Pagina 16 - Technical Specifications

Technical description DRYPOINT RA 80 – 720 23 5.13. Refrigerant Pressure Switches PA-PB-PV As operation safety and protection of the dryer a seri

Pagina 17 - Technical Specifications

Technical description 24 DRYPOINT RA 80 – 720 5.16. DMC14 Electronic Instrument (Air Dryer Controller) set Button - access the set-up. esc Button

Pagina 18

Technical description DRYPOINT RA 80 – 720 25 5.17. DMC20 Electronic Instrument (Air Dryer Controller) PQS0011 1. Back-lighted LCD display 8. Led

Pagina 19 - 5. Technical description

Technical description 26 DRYPOINT RA 80 – 720 5.17.2 ALARMS Any alarm condition is indicated by the flashing of the [9] led "Alarm" and

Pagina 20 - Flow Diagram (Water-Cooled)

Technical description DRYPOINT RA 80 – 720 27 • DewPoint Set : Not Used. • Diff. DewPoint : Not Used. • E Drain Time : Not Used. • E Drain Pause :

Pagina 21 - 5.6. Condenser (Air-Cooled)

Technical description 28 DRYPOINT RA 80 – 720 SET-UP PARAMETERS TABLE Parameter Description Adjustment Range Std Value Pass Code ? Pass

Pagina 22 - 5.12. Hot Gas By-pass Valve

Technical description DRYPOINT RA 80 – 720 29 5.17.5 REMOTE ALARM SIGNAL A voltage free contact is provided for remote signalling the sum of any a

Pagina 23 - DRYPOINT RA 80 – 720 23

Index DRYPOINT RA 80 – 720 3 1. Safety rules...

Pagina 24 - 24 DRYPOINT RA 80 – 720

Technical description 30 DRYPOINT RA 80 – 720 DATABASE Below is a list of the parameter description, type and address of data on DMC20 : Data Desc

Pagina 25 - DRYPOINT RA 80 – 720 25

Technical description DRYPOINT RA 80 – 720 31 5.18. Electronic level controlled condensate drain BEKOMAT The electronic level controlled dra

Pagina 26 - 26 DRYPOINT RA 80 – 720

Maintenance, troubleshooting, spares and dismantling 32 DRYPOINT RA 80 – 720 6. Maintenance, troubleshooting, spares and dismantling 6.1. Control

Pagina 27 - DRYPOINT RA 80 – 720 27

Maintenance, troubleshooting, spares and dismantling DRYPOINT RA 80 – 720 33 6.2. Troubleshooting Only qualified personnel should perform tro

Pagina 28

Maintenance, troubleshooting, spares and dismantling 34 DRYPOINT RA 80 – 720  DewPoint too low.  The fan is always ON - PV pressure switch is fa

Pagina 29 - Technical description

Maintenance, troubleshooting, spares and dismantling DRYPOINT RA 80 – 720 35  DMC20- The “alarm” lED is on.  One of the following appears on t

Pagina 30 - Technical description

Maintenance, troubleshooting, spares and dismantling 36 DRYPOINT RA 80 – 720 6.3. Spare Parts The suggested spare parts list will enable you to pr

Pagina 31

Maintenance, troubleshooting, spares and dismantling DRYPOINT RA 80 – 720 37 DRYPOINT RA Electronic Instrument DMC14 Electronic Instrument

Pagina 32 - 32 DRYPOINT RA 80 – 720

Maintenance, troubleshooting, spares and dismantling 38 DRYPOINT RA 80 – 720 DRYPOINT RA Electronic Instrument DMC14 Electronic Instrument

Pagina 33 - 6.2. Troubleshooting

Maintenance, troubleshooting, spares and dismantling DRYPOINT RA 80 – 720 39 6.4. Maintenance operation on the refrigerating circuit CAUTION! Re

Pagina 34 - 34 DRYPOINT RA 80 – 720

Index 4 DRYPOINT RA 80 – 720 7.2. Exploded View...

Pagina 35 - DRYPOINT RA 80 – 720 35

List of attachments 40 DRYPOINT RA 80 – 720 7. List of attachments 7.1. Dryers Dimensions 7.1.1. Dryers Dimensions DRYPOINT RA 80-100 /AC

Pagina 36 - 6.3. Spare Parts

List of attachments DRYPOINT RA 80 – 720 41 7.1.3. Dryers Dimensions DRYPOINT RA 180-300 /AC 7.1.4. Dryers Dimensions DRYPOINT RA 360/AC

Pagina 37

List of attachments 42 DRYPOINT RA 80 – 720 7.1.5. Dryers Dimensions DRYPOINT RA 400-600 /AC 7.1.6. Dryers Dimensions DRYPOINT RA 720 /AC

Pagina 38

List of attachments DRYPOINT RA 80 – 720 43 7.1.7. Dryers Dimensions DRYPOINT RA 80-100 /WC 7.1.8. Dryers Dimensions DRYPOINT RA 120-160 /WC

Pagina 39 - DRYPOINT RA 80 – 720 39

List of attachments 44 DRYPOINT RA 80 – 720 7.1.9. Dryers Dimensions DRYPOINT RA 180-300 /WC 7.1.10. Dryers Dimensions DRYPOINT RA 360 /WC

Pagina 40 - 7. List of attachments

List of attachments DRYPOINT RA 80 – 720 45 7.1.11. Dryers Dimensions DRYPOINT RA400-600 /WC 7.1.12. Dryers Dimensions DRYPOINT RA 720 /WC

Pagina 41 - List of attachments

List of attachments 46 DRYPOINT RA 80 – 720 7.2. Exploded View 7.2.1. Exploded view table of components 1 Alu-Dry Module 21 Bekomat drainer

Pagina 42 - List of attachments

List of attachments DRYPOINT RA 80 – 720 47 7.2.2. Exploded view DRYPOINT RA 80-100

Pagina 43

List of attachments 48 DRYPOINT RA 80 – 720 7.2.3. Exploded view DRYPOINT RA 120-160

Pagina 44

List of attachments DRYPOINT RA 80 – 720 49 7.2.4. Exploded view DRYPOINT RA 180-360

Pagina 45

Safety rules DRYPOINT RA 80 – 720 5 1. Safety rules 1.1. Definition of the Conventional Signs Used in This Manual Carefully read instruction man

Pagina 46 - 7.2. Exploded View

List of attachments 50 DRYPOINT RA 80 – 720 7.2.5. Exploded view DRYPOINT RA 400-720

Pagina 47

List of attachments DRYPOINT RA 80 – 720 51 7.3. Electrical Diagram 7.3.1. Electrical Diagram table of components IG : Main switch K : Compres

Pagina 48

List of attachments 52 DRYPOINT RA 80 – 720 7.3.2. Electrical Diagram DRYPOINT RA 80-160 - Electronic Instrument DMC14 013245 6789SUPPLYmin 4G2.5

Pagina 49

List of attachments DRYPOINT RA 80 – 720 53 7.3.3. Electrical Diagram DRYPOINT RA 80-160 - Electronic Instrument DMC14 T1POWERAhttp:// www.beko.d

Pagina 50

List of attachments 54 DRYPOINT RA 80 – 720 7.3.4. Electrical Diagram DRYPOINT RA 80-160 - Electronic Instrument DMC14 http:// www.beko.deBEKO TE

Pagina 51 - 7.3. Electrical Diagram

List of attachments DRYPOINT RA 80 – 720 55 7.3.5. Electrical Diagram DRYPOINT RA 80-160 - Electronic Instrument DMC20 0132456789SUPPLYmin 4G2.5S

Pagina 52

List of attachments 56 DRYPOINT RA 80 – 720 7.3.6. Electrical Diagram DRYPOINT RA 80-160 - Electronic Instrument DMC20 0132456789Rev :Drawing no.

Pagina 53

List of attachments DRYPOINT RA 80 – 720 57 7.3.7. Electrical Diagram DRYPOINT RA 80-160 - Electronic Instrument DMC20 013245 6789Rev :Drawing no

Pagina 54

List of attachments 58 DRYPOINT RA 80 – 720 7.3.8. Electrical Diagram DRYPOINT RA 180-360 - Electronic Instrument DMC14 013245 6789SUPPLYmin 4G2.

Pagina 55

List of attachments DRYPOINT RA 80 – 720 59 7.3.9. Electrical Diagram DRYPOINT RA 180-360 - Electronic Instrument DMC14 T1POWERAhttp:// www.beko.

Pagina 56

Safety rules 6 DRYPOINT RA 80 – 720 1.2. Warnings DANGER! Compressed air! Compressed air is a highly hazardous energy source. Never work on the

Pagina 57 - DRYPOINT RA 80 – 720 57

List of attachments 60 DRYPOINT RA 80 – 720 7.3.10. Electrical Diagram DRYPOINT RA 180-360 - Electronic Instrument DMC14 0123456789PVRPBPATV212TE

Pagina 58 - 58 DRYPOINT RA 80 – 720

List of attachments DRYPOINT RA 80 – 720 61 7.3.11. Electrical Diagram DRYPOINT RA 180-360 - Electronic Instrument DMC20 0132456789SUPPLYmin 4G2.

Pagina 59 - DRYPOINT RA 80 – 720 59

List of attachments 62 DRYPOINT RA 80 – 720 7.3.12. Electrical Diagram DRYPOINT RA 180-360 - Electronic Instrument DMC20 0132456789Rev :Drawing n

Pagina 60 - 60 DRYPOINT RA 80 – 720

List of attachments DRYPOINT RA 80 – 720 63 7.3.13. Electrical Diagram DRYPOINT RA 180-360 - Electronic Instrument DMC20 0132456789Rev :Drawing n

Pagina 61 - DRYPOINT RA 80 – 720 61

List of attachments 64 DRYPOINT RA 80 – 720 7.3.14. Electrical Diagram DRYPOINT RA 400-720 - Electronic Instrument DMC14 0132456789Rev :Drawing n

Pagina 62

List of attachments DRYPOINT RA 80 – 720 65 7.3.15. Electrical Diagram DRYPOINT RA 400-720 - Electronic Instrument DMC14 0132456789Rev :Drawing n

Pagina 63

List of attachments 66 DRYPOINT RA 80 – 720 7.3.16. Electrical Diagram DRYPOINT RA 400-720 - Electronic Instrument DMC14 0132456789Rev :Drawing n

Pagina 64

List of attachments DRYPOINT RA 80 – 720 67 7.3.17. Electrical Diagram DRYPOINT RA 400-720 - Electronic Instrument DMC20 0132456789Rev :Drawing n

Pagina 65

List of attachments 68 DRYPOINT RA 80 – 720 7.3.18. Electrical Diagram DRYPOINT RA 400-720 - Electronic Instrument DMC20 0132456789Rev :Drawing n

Pagina 66

List of attachments DRYPOINT RA 80 – 720 69 7.3.19. Electrical Diagram DRYPOINT RA 400-720 - Electronic Instrument DMC20 0132456789Rev :Drawing n

Pagina 67

Installation DRYPOINT RA 80 – 720 7 1.4. Instructions for the use of pressure equipment according to PED Directive 97/23/EC To ensure the safe ope

Pagina 68

------------------------------------------------------------------------------------------------------------------------------------------------

Pagina 70

DRYPOINT RA 80-720_manual_en_2009-11 Subject to technical changes without prior notice; errors not excluded. Original instructions are in ENGLISH.

Pagina 71

Installation 8 DRYPOINT RA 80 – 720 2.2. Storage SCC0001 Even when packaged, keep the machine protected from severity of the weather. Keep

Pagina 72

Installation DRYPOINT RA 80 – 720 9 2.4. Installation layout 1 Air compressor 2 Aftercooler 3 Condensate separator 4 Pre-Filter (min. 5 micron)

Commenti su questo manuale

Nessun commento

Friedrich MC12Y3JM manuali

Manuali dei proprietari e guide per l'utente per Climatizzatori a split Friedrich MC12Y3JM.
We fornisce 1 manuali pdf Friedrich MC12Y3JM per scaricare gratuitamente in base al tipo di documento: Brochure






Più prodotti e manuali per Climatizzatori a split Friedrich

Modelli Tipo di Documento
PDE07R3SG Brochure   Friedrich PDE07R3SG 2014 Specialty Product Brochure, 44 pagine
M24DYFKIT Manuale delle Istruzioni   Friedrich M24DYFKIT Installation Instruction Manual- 9/12 Indoor Units, 10 pagine
MM09YJ Manuale   Friedrich MM09YJ Ductless Universal Floor Ceiling Model Operation Manual, 17 pagine
SH20M50A Manuale   Friedrich SH20M50A Hazardgard Parts Manual, 16 pagine
MR24DY3JM29K Brochure   Friedrich HM12YJ Friedrich 2014 Commercial Ductless Brochure, 36 pagine
MM09YJ Manuale   Friedrich MM09YJ Ductless Model M30CG & M36CG Operation Manual [en] , 20 pagine